Onzen Chemical Levels Low
The following is a list of reasons for Low Onzen Chemicals:
Spa has recently been used and needs time to generate more sanitizer
Low Onzen Duration set in Settings
Poor Niche connection to generator
Faulty Electrode
Faulty Niche
Faulty Generator
Faulty Fuse
Faulty Motherboard
Chemical levels are low after checking with test strips. Set Onzen duration to 24hrs and save settings. If spas has been used a lot recently wait 24 hours and re-check levels. Once chemical levels are balanced readjust Onzen operations to the desired time 1-24 hours. ONZEN Output Electrode should start to generate smoke continually. Confirm Smoke is being generated for at least a 30 minute period.
Step 1. Enter Filtration Options Through Topside Controller Press the Filter button (pump 5 on epics) to enter into your filtration options. Your display will show “SETT” and from here you will be able to choose your settings.
Step 2. Ozone Cycle Duration Through Topside Controller Press your Filter/Pump 5 button again to display your first option. This is your Ozone Cycle Duration. * Peak II only, if Peak 1 is installed ozone will run during filtration.
Step 3. Setting Ozone Duration Through Topside Controller Use your arrow keys to select your Ozone Cycle Duration. You can select from 1 to 24 hours per day.
Step 4. Enter Onzen Settings Through Topside Controller Press your Filter/Pump 5 button again until you see 0n02. Your display will now show the settings for your Onzen system. 5 5 5 16 Onzen Technical Guide Steps to help Set Filtration & Onzen Settings Continued
Step 5. Onzen Cycle Duration Use your arrow keys to select your Onzen Cycle Duration. You can select from 1 to 24 hours per day. * Cycles are divided into 4 ie: If 8 hours is selected, the system will perform 4 x 2 hour cycles per day.
Step 6. Filter Duration Press your Filter/Pump 5 button again. Your display will now show the settings for your Filter Duration.
Step 7. Setting Filter Duration Use your arrow keys to select your Filter Duration in hours. You can select from 0 to 6 hours, the number of hours your filtration will run each time.
Step 8. Filter Cycle Frequency Press your Filter/Pump 5 button again. Your display will now show the settings for your Filter Cycle Frequency.
Step 9. Setting Filter Cycle Frequency Use your arrow keys to select your Filter Cycle Frequency You can select from 1 to 4 times per day.
Does the Onzen Electrode generate smoke?